ARIES G
High-efficiency chiller for medium and large HVAC systems. Fitted with scroll compressors, high-efficiency heat exchangers and R454B refrigerant for lasting energy savings.

Mode
Cooling
Heating
Heating and cooling
Cooling capacity
228 - 1303 kW
Installation
Outdoor
Refrigerant
R454B
Refrigerant (Propane)
R454B
Heat exchanger
Plate heat exchanger, shell-and-tube heat exchangers, heat recovery
Fans
Axial fan, EC axial fan
Compressors
Scroll compressors
Non-ferrous application
Optional
Advantages
- Environmentally friendly R454B refrigerant (GWP 466);
- High SEPR HT values compliant with the ErP Directive requirements (TIER 2, 01.01.2021 - base version) and SEPR MT (TIER 2, 02.07.2018 for the version with water outlet down to -10°C);
- SHE and SSN acoustic configurations with reduced noise levels;
- Wide application limits for commissioning and operation, even in unfavourable operating conditions;
- Wide range of accessories and kits for easy installation;
- Easy access to all components;
- Advanced electronic controller with built-in web server.
Technical Characteristics
- Environmentally friendly R454B refrigerant;
- 4 or 6 scroll compressors in 2 independent refrigeration circuits;
- Crankcase heater and phase monitoring;
- shell-and-tube evaporator;
- Victaulic connection kit for all models;
- Electronic expansion valves;
- Axial fans with die-cast aluminium blade profiles, fitted with protective guards;
- Control cabinet protection rating IP54;
- Microprocessor electronic controller with touchscreen for the user;
- Factory refrigerant charge, oil charge and operational test;
- Thorough factory checks and testing;
- Modbus RS485 interface for connection to monitoring systems;
- Master/slave configuration to control two systems.
Versions
- HE - base acoustic configuration;
- SHE – silent acoustic configuration;
- SSN – super-silent acoustic configuration;
Accessories
- Vibration damper kit;
- Remote user terminal replicated as a kit;
- xWEB300D EVO monitoring system;
- Module control kit for xDRIVE controllers (master/slave from 3 to 8 systems).
Options
- MWT configuration for low water outlet temperatures down to -10 °C;
- Equipment for low ambient temperatures down to -20°C;
- Stainless steel shell-and-tube evaporator;
- Single or dual water pump (one on standby) with low or medium head;
- water storage tank;
- Anti-freeze heater for evaporator, pump(s) and tank;
- Compressor shut-off valves;
- Soundproofed covers for the compressors (standard equipment for EHC);
- Soundproofed enclosure for tandem or trio compressors (standard equipment for SSN);
- High-efficiency EC fans (standard equipment for SSN);
- Full heat recovery;
- Microchannel condenser coil;
- Protective coating for condenser coils, suitable for installation in aggressive environmental conditions;
- Metal mesh filter to protect the condenser coils;
- Soft starter for a 20% reduction in the system's starting current.
Applications